Reference About 7 min read

Safety impact checklist

Identify the equipment affected by a control change and the person authorised to approve it. Review the physical consequences through the site's safety process.

Sources and scopeSource record 25 August 2026

Technical source record: 25 August 2026. Check the linked documentation for current product requirements.

Decision and escalation framework only; it supplies no life safety, egress, fire, electrical, functional safety, building code, dispatch, labor, privacy, accessibility, or legal approval.

Verification and testing

Overview#

Mandatory boundary: observation and actuation are separate authorities. Observation can still affect availability, privacy, or load; actuation can create physical consequences even when an API calls it “test,” “momentary,” “acknowledge,” “reset,” “maintenance,” or “configuration.”

This checklist doesn't authorise any action. Defer life safety, egress, fire, emergency communications, lifts, gates, locks, electrical work, dispatch, legal/privacy, accessibility, and regulatory decisions to the system owner, qualified designers/engineers, monitoring/emergency stakeholders, legal/privacy professionals, and applicable authority having jurisdiction (AHJ).

First classify the capability#

Observation#

Observation reads or receives data without an intended state change:

  • health/status, configuration inventory, capabilities, counters, time, and logs;
  • alarm/access/device events and current state;
  • live or recorded video/audio/metadata;
  • passive serial/network observation using an approved non intrusive method;
  • read only directory, credential, door, sensor, BMS, or OT values.

Observation is not impact free. A query can overload a controller; a subscription can exhaust queues; a media session can consume bandwidth; discovery can cause storms; live audio/video can violate privacy; a passive electrical tap can change bus loading; an acknowledgement looking read may consume server state. Apply authorisation, minimisation, query budgets, isolation, and stop conditions.

Actuation#

Actuation requests, enables, suppresses, or changes state or behaviour, including:

  • unlock, release, lock, lockdown, gate/barrier movement, lift floor access, door schedule or antipassback changes;
  • relay/output/GPIO activation, supervised input bypass, zone inhibit/isolate, alarm arm/disarm, acknowledge/silence/reset;
  • intercom call, listen/talk, DTMF function, paging, recorded announcement, emergency message;
  • PTZ movement, preset/tour, privacy mask change, focus/IR/heater/output, recording/retention deletion or export release;
  • controller/BMS/OT write, BACnet priority write, Modbus write, OPC UA method, KNX group write;
  • credential issuance/revocation, access level change, biometric enrolment/deletion, key/trust change;
  • firmware/configuration import, reboot/reset, PoE cycle, service stop, failover trigger, time set;
  • callback/subscription/configuration change that enables a later physical command.

An action is still actuation when its effect is indirect, delayed, scheduled, queued, retried, routed through a vendor cloud, or performed by changing policy rather than driving an output.

Classification matrix#

Class Description Examples Minimum disposition
O1, bounded observation Read only and expected to have low load/privacy consequence Bounded health read, synthetic offline trace parsing Named owner, least privilege, limits, privacy review, evidence
O2, consequential observation Sensitive, high volume, topology revealing, or potentially disruptive Live audio/video, broad discovery, controller walk, evidence export Explicit written authority, minimization, capacity plan, isolation/monitoring, stop rule
A1, controlled operational change Intended state change with bounded, reversible operational effect in exact approved context Noncritical lab configuration on isolated synthetic system Change control, separate actuator identity, preconditions, witness/telemetry, rollback and unknown outcome plan
A2, high impact actuation Can affect people, egress, security posture, alarm/dispatch, physical movement, evidence, electrical load, or safety system Unlock/lockdown, gate/lift, relay, alarm silence/reset, credential revocation, PoE restart of security device Qualified system/safety/legal/AHJ approval as applicable; production like isolation; independent stop authority; no autonomous repository execution
Prohibited/unsupported here No safe authority/evidence path or inherently out of scope for this KB Bypassing certified fire/egress controls, testing real dispatch, undocumented live writes Do not proceed; escalate to responsible qualified authority

Classification follows consequence, not HTTP method, SDK function name, UI label, protocol, or duration.

Observation checklist#

  • Read only capability and credential are technically separate from write/admin/actuation
  • Query/stream/subscription scope is the minimum resource, fields, resolution, duration, and rate
  • Endpoint supports the requested load and bounded pagination/batch size
  • Discovery/multicast/serial attachment can't create storms, transmit unexpectedly, or alter electrical behaviour
  • Live/recorded video, audio, access, location, biometric, credential, and topology data have purpose/access/retention approval
  • Logs and evidence redact secrets and unnecessary personal/security sensitive fields
  • Absence, stale state, unknown quality, clock error, and data gaps remain explicit
  • Observation isn't used as implicit authorisation for a later command
  • Stop on load increase, control latency, device instability, privacy scope breach, or unexpected state change

Actuation preconditions#

Don't expose or issue an actuation unless every applicable item has named evidence and approval:

  • Exact target asset, physical location, controlled function/load, product/firmware, and current operating mode positively identified
  • Requester, operator, service, device, and approving authority authenticated and separately authorised for this specific action/target/time
  • Current authoritative state, freshness/quality, dependencies, interlocks, occupancy/human presence, and environmental preconditions verified by approved system logic
  • Consequence analysis covers expected, duplicate, late, reordered, replayed, partial, failed, and unknown outcomes
  • Retry policy is operation specific; no blind retry after an ambiguous mutating result
  • Competing controllers, BACnet priorities, schedules, antipassback, emergency modes, local overrides, and manual controls understood
  • Fail safe/fail secure terminology is defined for the exact opening/system and code context, not assumed from a label
  • Positive physical completion evidence comes from the authoritative sensor/controller/process, not transport success alone
  • Rollback/recovery is physically possible, authorised, time bounded, and doesn't create a worse hazard
  • Independent monitoring, human stop authority, communications, incident response, and audit are active

For any A2 capability, use an isolated owner controlled setup with no live egress, dispatch, fire/life safety, public, production, or connected hazardous load unless the responsible qualified authorities explicitly own a controlled commissioning/acceptance procedure. Such a procedure is site, product, jurisdiction, and authority specific and falls outside this global reference.

Command lifecycle to preserve#

Milestone Meaning
Authorised Policy allowed the named principal to request the exact action
Submitted Client sent or durably queued a request
Transport accepted Peer/proxy acknowledged protocol receipt
Application accepted Target service accepted syntax and current preconditions
Commanded Controller attempted the output/state transition
Physically observed Authoritative sensor/process reported a resulting state
Operator acknowledged Human/workflow recognized the condition
Restored/reconciled System returned to intended stable state and checked for divergence

Never collapse these into one success flag. A timeout can leave outcome unknown; a 2xx, SOAP response, MQTT acknowledgement, OSDP reply, BACnet SimpleACK, Modbus response, or gRPC OK doesn't by itself prove safe physical completion.

High impact domains and mandatory deferral#

Domain Defer to and require
Doors, locks, egress, lockdown Access control owner, life safety/egress designer, security operations, fire/code/AHJ authorities as applicable
Gates, barriers, turnstiles, lifts Equipment manufacturer, qualified controls/safety engineer, site owner, accessibility/code/AHJ stakeholders
Fire, smoke control, emergency communications Certified system owner/provider, fire engineer/service, emergency stakeholders, AHJ; never bridge around listed/certified behaviour
Intrusion, duress, hold up, medical, panic, dispatch Monitoring center, response authority, subscriber/site owner, regulator/insurer as applicable; synthetic non dispatch routes only for development
Electrical, PoE, relays, GPIO, batteries, mains Manufacturer, qualified electrical designer/installer, applicable electrical/fire code and AHJ
Video/audio/biometrics/access history Privacy/legal, workforce/union where applicable, security owner, evidence custodian, accessibility stakeholders
BMS/OT writes Process/building owner, controls engineer, safety/environmental owner, change authority; preserve certified/local controllers

“Global” documentation can't decide these jurisdiction and system specific duties.

Unsafe automation patterns#

  • Event normalisation directly emits an unlock, lockdown, dispatch, silence, reset, or relay command.
  • A generic retry library repeats a mutation after timeout.
  • Health failure automatically power cycles a device with no state/cooldown/consequence gate.
  • A discovered address is trusted and immediately configured or controlled.
  • A video analytic alone makes an irreversible/high impact access or response decision.
  • An MQTT retained message or stale cache is interpreted as fresh physical state.
  • A credential/radio UID, RSSI, or raw UWB range is treated as sufficient authentication.
  • A gateway maps unknown vendor alarm codes to the nearest high priority standard meaning.
  • A monitoring integration acknowledges/silences upstream merely because downstream storage succeeded.
  • A “fail open” software fallback is used to solve an availability problem without certified system authority.

Stop conditions#

Stop work and preserve evidence if:

  • the target, connected load, physical effect, current state, or authority is ambiguous;
  • production credentials, real subscriber/dispatch routes, real people, or live emergency systems appear in an intended lab path;
  • a supposedly read only tool changes configuration/state or creates material load;
  • an action returns timeout/unknown outcome and safe physical state can't be independently confirmed;
  • interlocks, local controls, schedules, emergency override, or competing controller behaviour differs from the approved model;
  • certificate/identity, firmware, topology, wiring, power, or code status differs from the approved record;
  • monitoring, communication, stop authority, rollback, or audit becomes unavailable;
  • any person reports unsafe, inaccessible, coercive, privacy invasive, or unexpected behaviour.

Review record#

text
capability and exact target:
classification: O1 | O2 | A1 | A2 | prohibited/unsupported
intended and worst credible physical effect:
data/privacy effect:
owner and approving authorities:
standard/product/configuration evidence:
isolation proof:
preconditions and interlocks:
authoritative completion evidence:
unknown-outcome and retry rule:
rollback/recovery and stop authority:
legal/AHJ/electrical/life-safety decisions (external references only):
environment-validation record and owner:
residual risk acceptance and expiry:

Sources#